schneider electric

Results 151 - 175 of 211Sort Results By: Published Date | Title | Company Name
Published By: Schneider Electric     Published Date: Mar 06, 2018
"This paper contrasts the features of medium voltage fixed circuit breaker switchgear (FCBS) and existing withdrawable circuit breaker switgear (WCBS) designs. Modern FCBS design elements that are discussed include an internal disconnect for isolation and grounding of circuits and interlocked operation among disconnect, breaker, and grounding switch for improved safety. Furthermore, features such as lower maintenance, smaller footprint, and reduced life cycle costs that result from its simpler design will be explored. By comparing the traditional ANSI WCBS technology to that of the FCBS, this paper will demonstrate that the fixed design, which has gained widespread acceptance in global markets outside the United States, is a viable alternative to the withdrawable designs."
Tags : 
fixed circuit breaker, withdrawable circuit breaker, medium voltage, switchgear, arc flash, air insulated switchgear, gas insulated switchgear, ansi
    
Schneider Electric
Published By: Schneider Electric     Published Date: Sep 17, 2018
This on demand webinar contrasts the features of medium voltage fixed circuit breaker switchgear (FCBS) and existing withdrawable circuit breaker switgear (WCBS) designs. Modern FCBS design elements that are discussed include an internal disconnect for isolation and grounding of circuits and interlocked operation among disconnect, breaker, and grounding switch for improved safety. Furthermore, features such as lower maintenance, smaller footprint, and reduced life cycle costs that result from its simpler design will be explored. By comparing the traditional ANSI WCBS technology to that of the FCBS, this paper will demonstrate that the fixed design, which has gained widespread acceptance in global markets outside the United States, is a viable alternative to the withdrawable designs.
Tags : 
fixed circuit breaker, withdrawable circuit breaker, medium voltage, switchgear, arc flash, air insulated switchgear, gas insulated switchgear, ansi
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jan 27, 2017
The innovative 2SIS technology in Premset MV switchgear is ideal for harsh environments and drastically reduces the probability of an internal arc by fully enclosing all current carrying portions of the switchgear in high dielectric insulating epoxy. Complete the form to download the whitepaper and learn more about the advantages of 2SIS technology!
Tags : 
schneider electric, mv switchgear, shielded solid insulation system, 2sis, energy
    
Schneider Electric
Published By: Schneider Electric     Published Date: Apr 13, 2017
Energy costs have become an increasing contributor to pumping systems Total Cost of Ownership (TCO). In fact, energy cost represents 40% of the TCO of a typical pump. It is possible to reduce the electrical consumption by at least 30% utilizing Variable Speed Drives while decreasing maintenance costs associated with the mechanical driven system. In this complimentary white paper, learn how to reduce the TCO of your pumping system with a limited investment in three key areas: energy efficiency management, asset management, and energy cost management.
Tags : 
cost reduction, pumping system, gas facilities, energy efficiency management, asset management, energy cost management, investment management, energy saving, maintenance efficiency, electrical energy bill, electric industry
    
Schneider Electric
Published By: Box     Published Date: Jun 11, 2014
Global energy management giant based in France rolled out Box to 67,000 employees, enabled BYOD, and boosted productivity. Use Box for RFPs, vendor collaboration, executives, sales presentations. Cut server costs by 30%. Energy industry, large company, EMEA, global, sales LOB, BYOD, server replacement.
Tags : 
box, schneider, electric, vendor collaboration, global sales, lob, byod, server replacement
    
Box
Published By: Riverbed     Published Date: Feb 26, 2015
Riverbed Cloud Steelhead appliances support IT migration to cloud computing, SaaS and IaaS.
Tags : 
saas, cloud based, applications, it migration, iaas, cloud computing
    
Riverbed
Published By: Schneider Electric     Published Date: Mar 03, 2015
This paper discusses making realistic improvements to power, cooling, racks, physical security, monitoring, and lighting. The focus of this paper is on small server rooms and branch offices with up to 10kW of IT load.
Tags : 
it equipment, small server rooms, avoiding it downtime, how to avoid it downtime, improving small server rooms
    
Schneider Electric
Published By: Schneider Electric     Published Date: Mar 03, 2015
This white paper helps explain the differences between watts and VA and explains how the terms are correctly and incorrectly used in specifying power protection equipment.
Tags : 
measures for ups load sizing, how to avoid sizing errors, specifying power protection equipment
    
Schneider Electric
Published By: Schneider Electric     Published Date: Mar 03, 2015
This paper explains how to plan for VoIP power and cooling needs, and describes simple, fast, reliable, and cost effective strategies for upgrading old facilities and building new facilities.
Tags : 
voip power and cooling needs, building new facilities, upgrading old facilities, ip telephony applications
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2015
This paper describes the science and practical application of an improved method for the specification of cooling for wiring closets.
Tags : 
cooling, cooling strategies, cooling for wiring closets, wiring closets. cooling solution
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2015
This paper shows how virtualizing a data center’s IT resources can have certain consequences related to the physical infrastructure.
Tags : 
virtualisation, data center, cloud computing, cooling and management, cooling, power and cooling
    
Schneider Electric
Published By: Schneider Electric     Published Date: Dec 29, 2011
The rapid growth of consumer smartphones and tablets is having a dramatic impact on the enterprise. For employees, it's all about choice and convenience, but for organizations, it introduces new challenges and risks. Companies of all sizes are struggling with an ever-growing array of IT management and security concerns, as more and more business data moves to mobile devices. In this program, we address these concerns and reveal the secrets to unlock the power of mobility with two of the leading experts in the industry.
Tags : 
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 15, 2017
In today’s world of being “on” 24/7, data centers are at the core of business and viewed as the way to create competitive differentiation. Speed, efficiency, flexibility, and scale are now critical for winning the race to meet new connectivity and processing demands caused by the Internet of Things (IoT) and Big Data.
Tags : 
planning process, reference designs, cost analysis, design, site selection, schneider, electric
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 15, 2017
The reference guide lays out for data center managers a step-by step approach to data center consolidation. By breaking down the process into clear and identifiable actions – all of which are covered in the sections below – a data center consolidation becomes much more manageable, and the odds of its success much higher.
Tags : 
assessment, strategical planning, design, commission, operation, additional resources, schneider electric
    
Schneider Electric
Published By: Schneider Electric     Published Date: Aug 15, 2017
Schneider Electric is integrating datacenter infrastructure management (DCIM) software, big-data analytics and cloud services into the management of customers’ datacenters. Its recently launched StruxureOn cloud offering signals a new wave in datacenter operations, using a combination of machine learning, anomaly detection and event-stream playback to give operators real-time insights and alarming via their smartphones. More capabilities and features are planned, including predictive analysis and, eventually, automated action. Schneider’s long-term strategy is to build a partner ecosystem around StruxureOn, and provide digital services that span its traditional datacenter business.
Tags : 
incident tracking, historical trending, troubleshooting, operational analysis, prediction model, schneider equipment, maintenance, firmware updates
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2014
Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.
Tags : 
schneider, electric, data, infrastructure, convert data, business value
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2014
While many who invest in Data Center Infrastructure Management (DCIM) software benefit greatly, some do not. Research has revealed a number of pitfalls that end users should avoid when evaluating and implementing DCIM solutions. Choosing an inappropriate solution, relying on inadequate processes, and a lack of commitment / ownership / knowledge can each undermine a chosen toolset’s ability to deliver the value it was designed to provide. This paper describes these common pitfalls and provides practical guidance on how to avoid them.
Tags : 
schneider, electric, dcim, solution, invest, infrastructure, management, software
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2014
When faced with the decision of upgrading an existing data center, building new, or leasing space in a retail colocation data center, there are both quantitative and qualitative differences to consider. The 10-year TCO may favor upgrading or building over outsourcing, however, this paper demonstrates that the economics may be overwhelmed by a business’ sensitivity to cash flow, cash cross-over point, deployment timeframe, data center life expectancy, regulatory requirements, and other strategic factors. This paper discusses how to assess these key factors to help make a sound decision.
Tags : 
schneider, electric, data, infrastructure, upgrade, retail, outsource, own
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2014
70% of data center outages are directly attributable to human error according to the Uptime Institute’s analysis of their “abnormal incident” reporting (AIR) database1. This figure highlights the critical importance of having an effective operations and maintenance (O&M) program. This paper describes unique management principles and provides a comprehensive, high-level overview of the necessary program elements for operating a mission critical facility efficiently and reliably throughout its life cycle. Practical management tips and advice are also given.
Tags : 
schneider, electric, data, center, facility, operations, maintenance, management
    
Schneider Electric
Published By: Schneider Electric     Published Date: Jun 04, 2014
Standardized, scalable, pre-assembled, and integrated data center facility power and cooling modules provide a “total cost of ownership” (TCO) savings of 30% compared to traditional, built-out data center power and cooling infrastructure. Avoiding overbuilt capacity and scaling the design over time contributes to a significant percentage of the overall savings. This white paper provides a quantitative TCO analysis of the two architectures, and illustrates the key drivers of both the capex and opex savings of the improved architecture.
Tags : 
schneider, electric, data, center, scalable, integrated, power, cooling, capacity
    
Schneider Electric
Published By: Schneider Electric     Published Date: May 09, 2016
Internet use is trending towards bandwidth-intensive content and an increasing number of attached “things”. At the same time, mobile telecom networks and data networks are converging into a cloud computing architecture. To support needs today and tomorrow, computing power and storage is being inserted out on the network edge in order to lower data transport time and increase availability. Edge computing brings bandwidth-intensive content and latency-sensitive applications closer to the user or data source. This white paper explains the drivers of edge computing and explores the various types of edge computing available.
Tags : 
schneider electric, edge computing, data center, energy efficiency, data center energy, data centers
    
Schneider Electric
Published By: Schneider Electric     Published Date: May 09, 2016
In the broadening data center cost-saving and energy efficiency discussion, data center physical infrastructure preventive maintenance (PM) is sometimes neglected as an important tool for controlling TCO and downtime. PM is performed specifically to prevent faults from occurring. IT and facilities managers can improve systems uptime through a better understanding of PM best practices. This white paper describes the types of PM services that can help safeguard the uptime of data centers and IT equipment rooms. Various PM methodologies and approaches are discussed. Recommended practices are suggested.
Tags : 
schneider electric, edge computing, data center, energy efficiency, data center energy, preventive maintenance, tool for controlling, tco, data centers
    
Schneider Electric
Published By: Schneider Electric     Published Date: May 09, 2016
IT virtualization, the engine behind cloud computing, can have significant consequences on the data center physical infrastructure (DCPI). Higher power densities that often result can challenge the cooling capabilities of an existing system. Reduced overall energy consumption that typically results from physical server consolidation may actually worsen the data center’s power usage effectiveness (PUE). Dynamic loads that vary in time and location may heighten the risk of downtime if rack-level power and cooling health are not understood and considered. Finally, the fault-tolerant nature of a highly virtualized environment could raise questions about the level of redundancy required in the physical infrastructure. These particular effects of virtualization are discussed and possible solutions or methods for dealing with them are offered.
Tags : 
schneider electric, edge computing, data center, energy efficiency, data center energy, optimized power, virtualization, data centers
    
Schneider Electric
Published By: Schneider Electric     Published Date: Oct 04, 2012
A growing number of consolidation efforts have found success consolidating into an existing data center using the effective approach described in this paper.
Tags : 
schneider electric, data center, racks, power, power and cooling, energy savings, data center consolidation, network infrastructure, servers
    
Schneider Electric
Published By: Schneider Electric     Published Date: Oct 04, 2012
Rack-based cooling solutions are now appearing which take cooling capability to levels well in excess of 10 kW per rack. Download now to learn more.
Tags : 
schneider electric, data center, energy, data center, servers, blades, power and cooling, cooling, racks
    
Schneider Electric